SARO Freezer model HT 400

SKU: 323-2024

EAN: 4017337323937

Your price:  1.230,00 zzgl. gesetzlicher MwSt.

In stock

Wir machen Qualität bezahlbar!

  • Check Mark 24 Monate Garantie
  • Check Mark Kurze Lieferzeiten & Dropshipping
  • Check Mark Vor-Ort-Service auf gekennzeichnete Artikel

– Material: (housing) steel enamelled, white; (interior) plastic, white
– Door lockable
– Door stop changeable
– 7 evaporator grids, fixed (7 compartments)
– Digital temperature control (DIXELL)
– Static cooling
– Manual defrost
– Temp. -10 / -25 °C
– Connection: 230 V – 50 Hz – 0.210 kW
– Grids (fixed): 7x W 431 x D 415 mm
– Volume: 361 liters
– Internal dimensions: W 510 x 485 x 1620 mm
– External dimensions: W 600 x D 585 x H 1850 mm
– 2 adjustable feet + 2 castors (rear)
– Weight: 95kg
– Refrigerant: R600a
– Sound level: approx. 37dB(A)

Weight 95,00 kg
Dimensions 585 × 600 × 1850 mm
Width (inside)

510

Depth (inside)

485

Height (inside)

1620

Rack quantity + dimensions in mm (W/D)

Roste (fest): 7x B 431 x T 415 mm

Item capacity in litres

361,000

Temperature range

-10 / -25 °C

Noise level (dB)

ca. 37 dB(A)

Connection type

Normalstrom

Connection values

230 V – 50 Hz – 0,210 kW

On-site service (Germany only)

Nein

Country of origin

CN

Customs tariff number

84181020

Hersteller: Saro Gastro-Products GmbH - Sandbahn 6 - 46446 Emmerich am Rhein - DEUTSCHLAND / GERMANY - info@saro.de - www.saro.de

Nicht erforderlich. Hersteller ist in der EU ansässig.

Safety and Warning Instructions

- Place the device exclusively on a stable, level surface.
- Ensure that the mains voltage matches the specifications on the rating plate.
- Children and unauthorized persons must not operate or misuse the device.
- Do not block or cover the ventilation slots to prevent overheating and inefficient cooling.
- Do not operate the device near heat sources, direct sunlight, or in damp environments.
- If visible damage or malfunctions occur, immediately stop operation and contact the authorized dealer.
- The refrigerant is flammable; avoid damage to the cooling circuit. In case of a leak, ventilate the room thoroughly and avoid open flames.
- After transporting or tilting the device significantly, let it stand upright for at least 24 hours before switching it on.
- Before cleaning, switch off the device, unplug it, and allow it to fully defrost.
- Never clean the device with a water jet.
- Maintenance and repair work must only be carried out by qualified personnel.
- Do not use mechanical devices or tools to speed up the defrosting process, as this could damage the cooling circuit.
- After power outages or disconnection from the power supply, wait at least 5 minutes before restarting the device.
- Keep the door open only as long as necessary to minimize energy loss and maintain cooling efficiency.

×
×